Autoclavable Cleanroom Coverall Suit for Grade A/B/C Areas – MD-2A0402

MIDPOSI MD-2A0402 Autoclavable Cleanroom Coverall Suit is a reusable, washable and steam-sterilizable one-piece garment designed for Grade B+A and Grade C pharmaceutical clean areas. Made from polyester filament with conductive fibers, it offers low-lint performance, anti-static protection, high barrier performance and comfortable movement for sterile-area personnel.

  • Part No.: MD-2A0402
  • Category: Autoclavable Cleanroom Coveralls
  • Material: Polyester filament with conductive fibers
  • Applicable Areas: Grade B+A and Grade C
  • Features: Low-lint, anti-static, washable, autoclavable, breathable and reusable
  • Used with: Sterilizable goggles, 3D masks, tall boots, clean shoes, heel-less shoes and sterile gloves

Additional information

MIDPOSI Autoclavable Cleanroom Coveralls

Autoclavable Cleanroom Coverall Suit for Grade A/B/C Areas – MD-2A0402

MIDPOSI MD-2A0402 Cleanroom Coverall Suit is a reusable, washable and steam-sterilizable one-piece cleanroom garment designed for pharmaceutical clean areas, sterile areas and controlled production environments. The jacket and trousers are connected together to provide full-body coverage and reduce exposure gaps during cleanroom movement.

Made from polyester filament with conductive fibers woven through the fabric, this clean aseptic coverall suit provides anti-static performance, low particle release, high barrier performance, dust-control capability and comfortable wear for Grade B+A and Grade C cleanroom personnel.

Part No. MD-2A0402
Category Autoclavable Cleanroom Coveralls
Material Polyester filament with conductive fibers
Applicable Areas Grade B+A and Grade C
MIDPOSI MD-2A0402 autoclavable cleanroom coverall suit for pharmaceutical clean areas

Key Features of MD-2A0402 Cleanroom Coverall Suit

The MD-2A0402 coverall is engineered for pharmaceutical cleanroom users who need anti-static protection, dust-control performance, reusable garment durability and practical gowning comfort.

01

One-Piece Coverage

The jacket and trousers are connected together to improve body coverage and reduce separation during movement.

02

Polyester Filament Fabric

Made from polyester filament material with conductive fibers woven into the fabric structure.

03

Anti-Static Performance

Designed to help release electrostatic charge from the human body and support dust-free cleanroom work.

04

Autoclavable and Washable

Can be steam sterilized at 121°C for 30 minutes and is suitable for controlled machine washing.

05

Low Dust Adhesion

The fabric is designed to avoid dust generation and reduce dust adhesion during cleanroom operations.

06

Breathable and Comfortable

Especially recommended for cleanroom teams looking for a breathable coverall suit with comfort and durability.

Coverall Process Design

The MD-2A0402 cleanroom coverall uses high-temperature anti-static fabric and high-temperature-resistant accessories. It is designed for repeated cleanroom washing and steam sterilization workflows.

Design Item Description Cleanroom Benefit
One-Piece Structure Jacket and trousers are connected together. Improves body coverage and helps reduce exposure gaps.
Collar Design Hidden button design at the collar. Supports a cleaner appearance and more controlled closure.
Front Opening Front zipper with protected placket. Improves dressing convenience while reducing direct zipper exposure.
Neck Fixing Neck area is fixed with YKK snaps. Provides secure closure and better fit around the neck.
Back Cap Adjustment Back of cap can be designed with adjustable buckle. Improves fit for different users and cleanroom gowning needs.
Cuffs Elastic adjustment and internal cuffs. Reduces sleeve opening gaps and supports better personnel control.
Foot Opening Five-claw buckle adjustment at foot opening. Improves closure around lower leg and shoe/boot interface.
Zipper Structure Front diagonal open zipper and crotch opening zipper-type coverall. Supports easier dressing, movement and operation in cleanroom work.

Cleanroom Coverall Parameters

MIDPOSI MD-2A0402 is designed for cleanroom garment programs where anti-static performance, low-lint behavior, repeated washing resistance and steam sterilization stability are important.

Parameter Product Description
Anti-Static Performance Original yarn and silk processing technology help provide excellent anti-static performance and long use life. The garment can effectively help release electrostatic charge from the human body.
Dust Control The clothing itself is designed not to generate dust, not to absorb dust easily, and to provide good barrier performance for controlled environments.
Fabric Strength High-density, high-strength cleanroom fabric supports durability, washing resistance and abrasion resistance.
Washing Resistance Designed for repeated cleanroom washing. Washing resistance can reach ≥100 times under proper garment management.
Autoclave Resistance Can withstand steam sterilization at 121°C for 30 minutes. Suitable for repeated autoclave cycles when used according to facility procedures.
Seam Process Full overlocking process, once formed, supports better dustproof performance and garment durability.
Cleanroom Suitability Can be used for 10–10000 level cleanroom applications depending on garment configuration, facility SOP and validation requirements.

This product is especially recommended as a breathable cleanroom coverall suit for pharmaceutical clean areas that require comfort, low-lint performance and repeated cleaning compatibility.

Cleanroom Sterile Coverall Selection Guide

When selecting a cleanroom coverall suit, comfort, anti-static design and fabric structure should be considered together with the cleanroom grade and gowning procedure.

A

Easy to Wear and Move

One-piece cleanroom clothing should be easy to wear and remove, while still allowing comfortable movement during cleanroom work.

B

Minimize Exposed Metal

Electrostatic cleanroom clothing should avoid exposed metal accessories. If buttons or zippers are required, they should not be directly exposed when worn.

C

Use Anti-Static Fabric

The garment fabric should use full anti-static cleanroom fabric and should not use ordinary lining materials.

Products Used Together With MD-2A0402

The cleanroom coverall should be used as part of a complete gowning system. Accessories should be selected according to the facility cleanroom grade, personnel entry procedure and contamination-control strategy.

Compatible Accessories

  • Sterilizable goggles
  • Three-dimensional cleanroom masks
  • Tall cleanroom boots
  • Full cleanroom shoes
  • Heel-less clean shoes
  • Sterile cleanroom gloves

Applicable Cleanroom Areas

The MD-2A0402 cleanroom coverall can be used in pharmaceutical clean areas and sterile-area gowning programs depending on facility SOPs.

Grade B+A Grade C Grade A Grade B

Care and Maintenance Recommendations

Proper washing and sterilization management is important for reusable cleanroom coveralls. Ordinary washing environments are not recommended because dust, fibers, detergent residues and microorganisms may attach to the garment during washing, bundling, transport or handling.

Reusable cleanroom garments should be cleaned by a professional cleanroom laundry or dust-free purification cleaning provider. A controlled laundry process helps maintain low-lint performance, fabric cleanliness, anti-static function and garment suitability for cleanroom use.

The final washing frequency should be defined by the facility SOP. Some cleanroom garments may be laundered weekly, while more demanding pharmaceutical operations may require daily cleaning or sterilization.

Need Autoclavable Cleanroom Coveralls for Grade A/B/C Areas?

MIDPOSI can support reusable, washable and autoclavable cleanroom coveralls for pharmaceutical clean areas, sterile zones, laboratories and controlled environments. Share your cleanroom grade, fabric requirement, garment style and sterilization workflow, and our team can recommend suitable options.

We strive to make our clients happy

So, let's be happy together

about us 8888

It's Free!

《9 Deadly Pitfalls of Sourcing Cleanroom Garments in China》

e book 400
22

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@midposi.com”

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “*@midposi.com”