Maintains its electrical properties according to EN 1149-1 after 80 normal washings.
Washing instructions:
Autoclavable up to 121° C
Do not bleach
Do not allow contact with strong acid or alkali Electrical properties
EN61340-5-1 Electrical properties maintained after more than 100 Industrial launderings
Electrical properties:
Test Items
Test standard
Typical values
Requirements
Point to point resistance Rp
EN 1149-1
105 – 107 Ω
RP 109 Ω
Decay time
EN 1149-1
0.5~0.9 Sec PeakVoltage≤150V
<2sec to 10% of intial Value(max peak voltage 1000v)